Sign In | Join Free | My himfr.com
Home > OLT Optical Line Terminal >

Ma5800X7 OLT Optical Line Terminal 112 GPON 2xMPLA 2xPILA 7xGPHF C SFP Module

HONGKING INDUSTRIAL CO., LIMITED
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Ma5800X7 OLT Optical Line Terminal 112 GPON 2xMPLA 2xPILA 7xGPHF C SFP Module from wholesalers
     
    Buy cheap Ma5800X7 OLT Optical Line Terminal 112 GPON 2xMPLA 2xPILA 7xGPHF C SFP Module from wholesalers
    • Buy cheap Ma5800X7 OLT Optical Line Terminal 112 GPON 2xMPLA 2xPILA 7xGPHF C SFP Module from wholesalers
    • Buy cheap Ma5800X7 OLT Optical Line Terminal 112 GPON 2xMPLA 2xPILA 7xGPHF C SFP Module from wholesalers
    • Buy cheap Ma5800X7 OLT Optical Line Terminal 112 GPON 2xMPLA 2xPILA 7xGPHF C SFP Module from wholesalers
    • Buy cheap Ma5800X7 OLT Optical Line Terminal 112 GPON 2xMPLA 2xPILA 7xGPHF C SFP Module from wholesalers
    • Buy cheap Ma5800X7 OLT Optical Line Terminal 112 GPON 2xMPLA 2xPILA 7xGPHF C SFP Module from wholesalers

    Ma5800X7 OLT Optical Line Terminal 112 GPON 2xMPLA 2xPILA 7xGPHF C SFP Module

    Ask Lasest Price
    Supply Ability : 10000pcs/Week
    Payment Terms : T/T,Western Union
    Certification : CE ROHS Anatel
    Price : Negociatable
    Delivery Time : 7-15days
    • Product Details
    • Company Profile

    Ma5800X7 OLT Optical Line Terminal 112 GPON 2xMPLA 2xPILA 7xGPHF C SFP Module

    Huawei MA5800 X7 112GPON OLT H901BPMB service subrack with 2xMPLA 2xPILA

    Huawei MA5800 X7 16GPON C+ bundle equipped with 2xMPLA, 2xPILA, 7xGPHF C+ SFP Module

    1+1 MPLA equipped, switching capacity 7 Tbit/s, 100 Gbit/s slot bandwidth

    1+1 PILA equipped, redundance -48V DC power

    1 PCS GPHF 16-Port GPON OLT Interface Board with 112 C+ SFP Module

    7 Slots Occupied, 0 Slots Remain

    2 power cable, 1 earth cable, 1 accessory package


    Switching Capacity3.6 Tbit/s
    Slot Bandwidth100 Gbit/s
    Service Slots7 slot occupied, 0 remain
    Power SupplyDC: -48V DC
    Number of Services EquippedService InterfaceEquippedService InterfaceEquipped
    GE/10GE8GPON112
    Mechanical specification
    Dimensions (W x D x H excluding mounting brackets)442.00 mm x 283.20 mm x 263.90 mm
    Dimensions (W x D x H, including mounting brackets)535.00 mm x 283.20 mm x 263.90 mm, for ETSI cabinet
    Working environment temperatureFor an indoor cabinet
    Configured with 1 subrack: -25°C to +65°C
    Configured with 2 subracks: -25°C to +55°C
    Power Consumption

    Static power consumption 164w

    Maximum power consumption 425w

    Typical power consumption 294.5w

    Atmosphere pressure61 kPa to 106 kPa
    Altitude< 4000 m


    Description:

    Huawei SmartAX MA5800 X7 NG OLT, 19inch, with 6U height 7 service slots, 200G throughput per slot, support GPON, 10G PON, 40G/100G PON ready; H901BPMB subrack equipped with 2xH901MPLA, 2xH901PILA

    Huawei MA5800 X7 NG OLT H901BPMB subrack equipped with 2xH901MPLA, 2xH901PILA

    Comes with 2PCS power cable, 1PCS earth cable, accessory package

    Huawei MA5800 X7 NG OLT MAX 7168 ONTs

    Chassis supports 7 Service Slots

    Supports GPON, 10G PON, smoothly evolve to 40G/100G PON

    Supports 4*GE/10GE upstream ports embedded in Main Control Board MPLA/MPLB

    Supports 16 port GPON interface card GPHF, GPSF

    Supports 8 port 10GPON interface card XGHD, TWED

    Support 262143 MAC address, 65536 ARP table

    Supports over 8 times MAC address and ARP table more than MA5680T

    Supports 1:64 eOTDR

    Supports DOCSIS 3.1 standard

    Product Specifications
    Switching capacity of the system

    H901MPLA/H902MPLA: 3.6 Tbit/s

    H901MPLB: 7 Tbit/s

    Maximum bandwidth per slotH901MPLB: 200 Gbit/s
    H901MPLA/H902MPLA: 100 Gbit/s
    Maximum number of MAC address262144
    Maximum number of ARP/routing entries131072
    Maximum number of concurrent 4K video users8000
    GPON ports112
    XG-PON ports112
    XGS-PON ports56
    GE/FE ports336
    10GE ports56
    Cabinet supportedN63E-22
    Board Supported
    Control Board
    H901MPLBIt provides 4 GE/10GE upstream transmission ports and supports load sharing. By default, MA5800 connects to upstream network through the control board
    H901MPLA/H902MPLA
    H901CKUASupports stratum-3 clock functions by working with MPLB and MPLA
    Upstream interface board
    H901NXEDEnhanced 8-port 10GE upastream interface board, supporting 10GE/GE Ethernet upstream transmission. NXED is used when upstream ports currently provided in MA5800 are not enough.
    Universal interface board
    H901CIUAProvides synchronous time/clock signal input&output interfaces, alarm parameter/Boolean value input&output interface. RS485 serial ports, and provides transparent transmission Ethernet ports.
    Service board
    H901GPHFProvides 16 GPON ports for access services
    H901GPSFProvides 16 GPON ports for home access services
    H901XGHDProvides 8 asymmetric 10G GPON ports for access services.
    H901TWEDProvides 8 symmetric 10G GPON ports for access services.
    H901EDSH32-channel E1 upstream board, supporting native TDM mode.
    H901OGHK48-port aggregated GE/FE optical interface board, supporting up to 48 channels of GE/FE
    H901OXHD8-port aggregated 10GE optical interface board, supporting GE/10GE Ethernet aggregation.
    Power board
    H901PILAProvides -48V DC input
    Fan Monitoring board
    H901FMLASupplier power to fans; controls and moniotes the fans
    H901FMMASupplier power to fans; controls and moniotes the fans
    Dimensions
    (W x D x H) (mm)
    6 U high and 19 inch wide
    Excluding mounting brackets: 442x268.7x263.9
    Including IEC mounting brackets: 482.6x268.7x263.9
    Including ETSI mounting brackets:535x268.7x263.9
    Maximum weight(including mounting brackets)26 kg
    Maximum input current40 A
    Power supplyPower supply mode: DC
    Working voltage range: -38.4 V to -72 V
    Rated voltage: -48 V / -60 V
    Ambient temperature-40°C to +65°C The MA5800 can start up at a lowest
    The MA5800 can start up at a lowest temperature of -25°C and run at -40°C.
    Note:The 65°C temperature refers to the highest temperature measured at the air intake vent of service subrack.
    Ambient humidity5% RH to 95% RH

    Q&A

    Q: What are the system specifications differences among MA5800 series OLT?

    A:

    ItemMA5800-X17MA5800-X15MA5800-X7MA5800-X2
    Switching capacity of the control boardH901MPLA/H901MPLB: 7 Tbit/sH901MPSC: 480 Gbit/s

    Maximum bandwidth per service slot (load sharing mode)

    H901MPLA: 100 Gbit/s
    H901MPLB: 200 Gbit/s
    H901MPSC: 80 Gbit/s
    Maximum number of concurrent 4K video users1600080002000

    Q: What are the physical specifications differences among MA5800 series OLT?

    A:

    ItemMA5800-X17MA5800-X15MA5800-X7MA5800-X2
    Rack type21inch19inch
    Maximum weight(including mounting brackets)45kg35kg26kg9.4kg
    Maximum input current60A40ADC power supply: 20A
    AC power supply: 8 A

    Q: What are the maximum number of ports in MA5800 series subrack?

    A:

    ItemMA5800-X17MA5800-X15MA5800-X7MA5800-X2
    GPON ports27224011232
    10G GPON ports1361205616
    GE/FE ports81672033632
    10GE ports1361205616
    E1 ports54448022464

    Q: What is the great improvement of MA5800?

    A: Great improvement:

    • Symmetric 10G GPON (XGS PON): Supports XGS PON , Improves the upstream bandwidth from 2.5G to 10G and enhances symmetric service supporting.

    • ONT energy saving: Supports the ONT sleep mode. Reduces ONU power consumption for environmental protection.

    • 8 times MAC address and ARP table than MA5680T and MA5683T.


    Q: Does MA5800 have new typical New Hardware Board?

    A: Yes, H901TWED, 8-port symmetric 10G GPON interface board, it works together with the optical network terminal (ONT) to provide 10G GPON access services.


    Q: How to configure Ring Check of the MA5800?

    A: The Ring Check feature enables the device to send the Ring Check packets periodically and monitors the Ring Check packets received on the user-side, cascade-side, and network-side to detect whether a loop occurs on the network of the carrier. If a loop occurs, the MA5800 deactivates the subscriber port on the loop and reports the corresponding alarm to the NMS. This ensures that the device runs in the normal state and that legal users are not affected.

    • Run the ring check enable command to enable the user-side ring network detection.

    • Run the ring check uplink detection enable command to enable the network-side ring network detection.

    • Run the ring check cascade detection enable command to enable the cascade-side ring network detection.


    Q: Why switchover occurs between the active and standby boards?

    A: Possible Causes:

    • The active/standby switchover command is manually executed.

    • The original active control board is faulty.

    • The physical port or line on the original active control board is faulty.

    • The active control board is faulty, causing a protective switchover of the system.

    • The clock daughter board of the original control board is faulty.

    • The system performs a periodical switchover.


    Q: How many 10 GE ports on MA5800?

    A: 8 x 10 GE SFP+ interface or 8 x GE SFP/eSFP interface.


    Q: Can MA5800 support 4K video?

    A: Each sub-rack supports up to 32K users with 100 Mbit/s of non-blocking bandwidth, letting everyone enjoy seamless 4K video.


    Q: Does MA5800 support the Multicast?

    A: Yes, it supports Layer 3 multicast networking, also supports IPv4 PIM SSM.

    • Protocol Independent Multicast-Source-Specific Multicast (PIM-SSM) enables a user host to rapidly join a multicast group if the user knows a multicast source address. PIM-SSM sets up a shortest path tree (SPT) from a multicast source to a multicast group, while PIM-SM uses rendezvous points (RPs) to set rendezvous point trees (RPTs). Therefore, PIM-SSM implements a more rapid join function than PIM-SM.

    • Different from the any-source multicast (ASM) model, the SSM model does not need to maintain an RP, construct an RPT, or register a multicast source.

    • The SSM model is based on PIM-SM and IGMPv3. The procedure for setting up a multicast forwarding tree on a PIM-SSM network is similar to the procedure for setting up an SPT on a PIM-SM network. The receiver's DR, which knows the multicast source address, sends Join messages directly to the source so that multicast data streams can be sent to the receiver's designated router (DR).


    Q: Does MA5800 support the VPLS?

    A: The Virtual Private LAN Service (VPLS), also called the Transparent LAN Service (TLS) or virtual private switched network service, is a Layer 2 VPN (L2VPN) technology that is based on Multi-Protocol Label Switching (MPLS) and Ethernet technologies.

    Quality Ma5800X7 OLT Optical Line Terminal 112 GPON 2xMPLA 2xPILA 7xGPHF C SFP Module for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: HONGKING INDUSTRIAL CO., LIMITED
    *Subject:
    *Message:
    Characters Remaining: (0/3000)